BoostBloC®

Heat

pump

post-heating

BoostBloC DN 25 (1")

PAW BoostBloC post-heating module - for a high heating and hot water convenience

SKU
67410GM
Prices are only visible for registered users.

Our offer is exclusively aimed at corporate clients.

Manufacturer:
PAW GmbH & Co. KG
Böcklerstr. 11 31789 Hameln
Germany
info@paw.eu
Operating data
Max. operating temperature: 85 °C
Dial thermometer: 0 - 120 °C
Max. operating pressure: 5 bar
Temperature difference: 10 K bei 700 l/h; 5 K bei 1.400 l/h
Kvs value: 5.5
Flow rate: 500 bis 2000 l/h
Torque: 5 Nm
Equipment
Dial thermometer: 0 - 120 °C
Shut-off valves: Ball valves with handle
Dimensions
Height: 520 mm
Width: 370 mm
Nominal diameter: DN 25
Depth: 190 mm
Installation length: 453 mm
Installation depth: 190 mm
Connection internal thread: 1"
Centre distance top: 110 mm / 90 mm
Centre distance bottom: 210 mm
Materials
Valves and fittings: Brass
Gaskets: AFM 34
Insulation: Armaflex
Return pipe: Steel
Cover: Polystyrol
Electrical data (heating/actuators)
Setting time 90°: 20 s
Heat pumps provide sufficient energy at different temperature conditions in order to offer a high heating and hot water convenience.For the case
that this is not sufficient, the PAW BoostBloC is activated and provides additional thermal energy via an instant water heater.

The post-heating module is a preassembled group of fittings for heat pump applications.All electronic components such as the instant water heater or the pump
can be isolated by means of the ball valves.They can thus be maintained easily without draining the heating or charging circuit system.
The PAW BoostBloC is mounted directly at the wall and serves to post-heat a storage tank.The system can be extended by further components as a domestic hot water module or a heating distribution manifold.

The station requires an additional controller and is normally actuated by the heat pump controller.It is connected to the external controller via
the enclosed small distribution manifold.Via a post-heating request (230 V) of the controller, the power contactor is actuated, which is integrated in the small distribution manifold.In the type with contactor,
there is no power control; only the one preset power (8.8 kW) of the tubular heating element is actuated.
Depending on the controller and connection type, the pump can be connected simultaneously to the heat generator or separately.
For an independent valve control of the integrated flow stratification, a continuous phase as well as a further switch contact are required.

Safety instructions
The installation and commissioning as well as the connection of electrical components require technical knowledge commensurate with a recognised vocational qualification as a fitter for plumbing, heating and air conditioning technology, or a profession requiring a comparable level of knowledge [specialist].
The following must be observed during installation and commissioning:
- relevant local and national regulations
- accident prevention regulations of the professional association
- instructions and safety instructions mentioned in these instructions.

CAUTION
Personal injury and damage to property!
The product must only be used in heating circuits filled with heating water according to VDI 2035 / Ö-Norm H 5195-1. The product must not be used in domestic water applications.

NOTICE
Material damage due to mineral oils!
Mineral oil products cause lasting damage to seals made of EPDM, whereby the sealant properties get lost. We do not assume liability nor provide warranty for damage to property resulting from sealants damaged in this way.
- It is imperative to avoid that the EPDM sealing elements of the unit get in contact with substances containing mineral oils.
- Use a lubricant based on silicone or polyalkylene and free from mineral oils, such as Unisilikon L250L and Syntheso Glep 1 of the Klüber company or a silicone spray.

ATTENTION
Damage to property!
It is imperative to avoid dry operation of the instant water heater in order to prevent material damage of the installation.
- Make super to provide a sufficient flow rate of heating water.
- When the flow is disturbed, the electric circuit must be immediately interrupted.