HeatBloC®
Heating
technology
Extension module DN 50
The installation may only be made by qualified experts.
A = 180 mm H = 225 mm L = 360 mm
Completely preassembled
Flow and return chamber 95 % thermally separated
Safety instructions The installation and commissioning as well as the connection of electrical components require technical knowledge commensurate with a recognised vocational qualification as a fitter for plumbing, heating and air conditioning technology, or a profession requiring a comparable level of knowledge [specialist]. The following must be observed during installation and commissioning: - relevant local and national regulations - accident prevention regulations of the professional association - instructions and safety instructions mentioned in these instructions.
NOTICE Material damage due to mineral oils! Mineral oil products cause lasting damage to seals made of EPDM, whereby the sealant properties get lost. We do not assume liability nor provide warranty for damage to property resulting from sealants damaged in this way. - It is imperative to avoid that the EPDM sealing elements of the unit get in contact with substances containing mineral oils. - Use a lubricant based on silicone or polyalkylene and free from mineral oils, such as Unisilikon L250L and Syntheso Glep 1 of the Klüber company or a silicone spray.
ATTENTION The covers at both ends of the modular distribution manifold must not be turned by 90°. This leads to a connection of the flow and return chamber, resulting in unwanted circulation. The connections must be directed to the front or to the back. Use the extension module in combination with PAW distribution manifolds only. Improper usage excludes any liability claims. The packaging materials are made of recyclable materials and can be disposed of with recyclable materials.