• Best quality
  • Quick assembly
  • Longevity

Friwa

DHW

technology

FriwaMicro up to 20 l/min

Domestic hot water preparation operating on the principle of a flow-type water heater
Withdrawal capacity: 2-20 l/min
Circulation: no

SKU
64000
Prices are only visible for registered users.

Our offer is exclusively aimed at corporate clients.

Manufacturer:
PAW GmbH & Co. KG
Böcklerstr. 11 31789 Hameln
Germany
info@paw.eu
Operating data
Max. operating temperature: 80 °C
Max. operating pressure primary: 3 bar
Max. operating pressure secondary: 10 bar
Kvs value primary: 2,6
Kvs value secondary: 1,9
Max. flow rate: 20 l/min
Transmission performance: 48 kW
Min. flow rate: 2 l/min
Equipment
Controller: no
Check valves: no
Shut-off valves: no
Sensors: no
Heat exchanger: E8ASH, 24 plates
Flow switch: Type 1.3​ l/min​
Thermostatic valve: Housing / valve plate: brass
Cartridge sensor: 30-60 °C
Circulation: no
Dimensions
Height: 420 mm
Width: 282 mm
Nominal diameter: DN 15 (½")
Depth: 265 mm
Installation length: 418 mm
Connection primary: ¾" int. thread
Connection secondary: ¾" int. thread
Connection circulation line: no
Centre distance primary: 65 mm
Centre distance secondary: 65 mm
Materials
Valves and fittings: Brass
Gaskets: EPDM / AFM34
Insulation: EPP
Piping: Stainless steel
Flow switch: Noryl
Cartridge sensor: Stainless steel
Thermostatic valve: Housing / valve plate: brass
Heat exchanger: Solder: copper,Plates + connecting pieces: stainless steel,coating (optional): based on silica
Design data (Friwa)
Cold water inlet temperature: 10 °C
Withdrawal capacity: min. flow rate: 2 l/min
Field of application:
Domestic hot water preparation operating on the principle of a flow-type water heater

Application range:
In solar thermal systems
In systems with solid fuel boilers, oil or gas boilers
Connection to a buffer tank
No domestic hot water tank necessary
Energy for heating the water is taken from the buffer tank

Operating data:
Max. operating pressure: primary = 3 bars, secondary = 10 bars
Max. operating temperature: 80 °C
Min. flow rate: 2 l/min
Max. flow rate: 20 l/min

The CE-conformity of the module has been certified according to DIN EN 60335 and SVGW.

*Indication of performance as per SPF test procedure

Safety instructions
The installation and commissioning as well as the connection of electrical components require technical knowledge commensurate with a recognised vocational qualification as a fitter for plumbing, heating and air conditioning technology, or a profession requiring a comparable level of knowledge [specialist].
The following must be observed during installation and commissioning:
- relevant local and national regulations
- accident prevention regulations of the professional association
- instructions and safety instructions mentioned in these instructions.

WARNING
Malfunction!
- The product must be integrated in the potential equalisation of the electric installation. This can be guaranteed by establishing a potential equalisation connection to the main potential connection according to regulations or by the connected pipe system.

NOTICE
Material damage due to mineral oils!
Mineral oil products cause lasting damage to seals made of EPDM, whereby the sealant properties get lost. We do not assume liability nor provide warranty for damage to property resulting from sealants damaged in this way.
- It is imperative to avoid that the EPDM sealing elements of the unit get in contact with substances containing mineral oils.
- Use a lubricant based on silicone or polyalkylene and free from mineral oils, such as Unisilikon L250L and Syntheso Glep 1 of the Klüber company or a silicone spray.