HeatBloC®
Heating
technology
HeatBloC® K36 DN 20 (¾")
Boiler charging set with thermal control valve
Field of application: Return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems
Recommended application range: up to 10 kW; 10 K up to 860 l/h
Opening temperature 45 °C (item no. 320353xx)
Opening temperature 60 °C (item no. 320363xx)
Field of application: Return flow temperature maintenance for solid fuel boilers, wood firing and stove heating systems
Recommended application range: up to 10 kW; 10 K up to 860 l/h
Opening temperature 45 °C (item no. 320353xx)
Opening temperature 60 °C (item no. 320363xx)
Operating data
Max. operating temperature:
110 °C
Dial thermometer:
0 - 120 °C
Output:
10 kW
Max. operating pressure:
6 bar
Temperature difference:
10 K
Kvs value:
2.5
Flow rate:
860 l/h
Equipment
Check valves:
1 x 200 mm wc
Dial thermometer:
0 - 120 °C
Shut-off valves:
Ball valves with handle
Opening pressure check valve:
200 mm wc
Number of check valves:
1
Dimensions
Height:
385 mm
Width:
180 mm
Nominal diameter:
DN 20 (¾")
Installation length:
347 mm
Connection generator:
¾" int. thread
Connection consumer:
¾" int. thread
Centre distance:
90 mm
Materials
Valves and fittings:
Brass
Gaskets:
EPDM
Insulation:
EPP
Flat-sealing connections ¾'' internal thread / 1" external thread
with 1" union nut for assembly on PAW distribution manifolds
with PAW mounting equipment, the HeatBloCs can be installed on wall brackets
Large ball valve handles,
easy handling, visible closing position
EnEV-compliant functional insulation
made of durable elastic EPP, complete insulation of valves and fittings, ventilation opening to cool the pump
the insulation for the distribution manifold is integrated in the heating circuit insulation
Free access to the pump head
by simply removing the front insulation shell
Check valve in the flow pipe
opposite to the pump, can be opened, 200 mm wc, spring-loaded, thus suited for horizontal and overhead installation
Thermal control valve with automatic bypass ensures that the boiler always keeps a minimum temperature (= opening temperature +/- 3 K) and prevents the boiler from contamination.
The K36 should always be used with a buffer tank, if not, a hydraulic separator is mandatory.
All water-carrying parts are made of brass
Full metal thermometers
can be pulled off, with immersion sleeve integrated in the ball valve
PAW heating pumps with high-efficiency (ECM) technology
fitted with 2 m cable, completely premounted, integrated in the insulation, pressure tested, with serial number, perfectly designed system, pump characteristics, EuP/ErP READY.
When electronically controlled high-efficiency pumps are used, the type of control ΔP-c (DeltaP = constant) must be set.
The pump can be entirely isolated.
No draining necessary during servicing.
with 1" union nut for assembly on PAW distribution manifolds
with PAW mounting equipment, the HeatBloCs can be installed on wall brackets
Large ball valve handles,
easy handling, visible closing position
EnEV-compliant functional insulation
made of durable elastic EPP, complete insulation of valves and fittings, ventilation opening to cool the pump
the insulation for the distribution manifold is integrated in the heating circuit insulation
Free access to the pump head
by simply removing the front insulation shell
Check valve in the flow pipe
opposite to the pump, can be opened, 200 mm wc, spring-loaded, thus suited for horizontal and overhead installation
Thermal control valve with automatic bypass ensures that the boiler always keeps a minimum temperature (= opening temperature +/- 3 K) and prevents the boiler from contamination.
The K36 should always be used with a buffer tank, if not, a hydraulic separator is mandatory.
All water-carrying parts are made of brass
Full metal thermometers
can be pulled off, with immersion sleeve integrated in the ball valve
PAW heating pumps with high-efficiency (ECM) technology
fitted with 2 m cable, completely premounted, integrated in the insulation, pressure tested, with serial number, perfectly designed system, pump characteristics, EuP/ErP READY.
When electronically controlled high-efficiency pumps are used, the type of control ΔP-c (DeltaP = constant) must be set.
The pump can be entirely isolated.
No draining necessary during servicing.