Solex|SolarBloC®

Solar

thermal

systems

SolarBloC® maxi Basic return station

Application range:
Low-Flow (= 0.25 l/minute per m² collector surface), up to 125 m² collector surface
High-Flow (= 0.5 l/minute per m² collector surface), up to 80 m² collector surface

Please note:
In order to guarantee a trouble-free function it is essential to carry out a hydraulic dimensioning/check.
SKU
7680210
Prices are only visible for registered users.

Our offer is exclusively aimed at corporate clients.

Operating data
Max. operating temperature: 120 °C
Dial thermometer: 0 - 160 °C
Max. operating pressure: 6 bar
Low-flow: = 0.25 l/min per m² of collector surface
High-flow: = 0.5 l/min per m² of collector surface
Equipment
Controller: on site
Check valves: 1 x 200 mm wc
Pressure gauge: 0-6 bar, resistant to high temperatures
Flow meter: 5-40 l/min
Dial thermometer: 0 - 160 °C
Shut-off valves: Ball valves
Sensors: no
Safety valve: 6 bar
Airstop: no
Dimensions
Height: 474 mm
Width: 244 mm
Nominal diameter: DN 25
Depth: 150 mm
Installation length: 394 mm
Connection primary: 1" int. thread
Materials
Valves and fittings: Brass
Gaskets: EPDM / AFM34
Insulation: EPP
Check valves: Brass
All fluid-carrying parts are made of brass

All connections ¾" internal thread

Premounted on steel wall bracket,
can be easily mounted to the wall with snap-in mechanism

Full port ball valves

Check valve in the return, can be opened, 200 mm wc, especially for solar systems.In order to prevent unwanted circulation, it is mandatory to mount an additional check valve in the flow on site (see below the item).

Ball valve key-actuated,
easy handling, no risk of scalding

Compact design insulation with optimised function made of durable elastic EPP;
100 % insulated valves and fittings, excellent ventilation and cooling of the pump

Solar safety group
Solar pressure relief valve 6 bars, pressure gauge resistant to high temperature 0-6 bars with valve, fill and drain valve for flushing and filling, flat sealing connection for an expansion tank

Full metal solar thermometer, 0-160 °C
can be pulled off, with immersion sleeve, integrated in the ball valve

Fully assembled with flat gaskets

With solar circulation pump by Grundfos or Wilo
already installed

Pump can be isolated,
so that it can be replaced without draining

Flowmeter
Volumetric flow meter with adjustable flow limiter and function control device, for temperatures up to 120 °C, measuring range 3-22 l/min

Flush and fill unit integrated
two fill and drain valves (on the flowmeter and on the safety group) permit flushing and filling the system