Solex|SolarBloC®

Solar

thermal

systems

SolarBloC® maxi Basic

Application range:
Low-Flow (= 0.25 l/minute per m² collector surface), up to 125 m² collector surface
High-Flow (= 0.5 l/minute per m² collector surface), up to 80 m² collector surface

Please note:
In order to guarantee a trouble-free function it is essential to carry out a hydraulic dimensioning/check.
SKU
782212
Prices are only visible for registered users.

Our offer is exclusively aimed at corporate clients.

Manufacturer:
PAW GmbH & Co. KG
Böcklerstr. 11 31789 Hameln
Germany
info@paw.eu
Operating data
Max. operating temperature: 120 °C
Dial thermometer: 0 - 160 °C
Max. operating pressure: 6 bar
Low-flow: = 0.25 l/min per m² of collector surface
High-flow: = 0.5 l/min per m² of collector surface
Equipment
Controller: SC2.3
Check valves: 2 x 200 mm wc
Pressure gauge: 0-6 bar, resistant to high temperatures
Flow meter: 5-40 l/min
Dial thermometer: 0 - 160 °C
Shut-off valves: Ball valves
Sensors: 2 x Pt1000 (enclosed, only for modules with controller)
Safety valve: 6 bar
Airstop: yes
Dimensions
Height: 653 mm
Width: 324 mm
Nominal diameter: DN 25 (1")
Depth: 160 mm
Installation length: 394 mm
Centre distance: 100 mm
Connection primary: 1" int. thread
Materials
Valves and fittings: Brass
Gaskets: EPDM / AFM34
Insulation: EPP
Check valves: Brass
The SolarBloC® maxi Basic is a compact and completely premounted solar station with optional controller.

All fluid-carrying parts are made of brass, fully assembled, self-sealing or flat gaskets.

All connections 1" internal thread

Steel wall bracket for simple assembly,
solar station can be plugged in

Full port ball valves

Check valve in the flow and return ball valve,
can be opened, 200 mm wc, especially for solar systems, prevent unwanted circulation

Large ball valve handles,
easy handling, visible closing position

Full metal solar thermometer 0-160 °C,
can be pulled off, with immersion sleeve integrated in the ball valve

Airstop in the flow line
for permanent deaeration of the solar fluid

Compact design insulation with optimised function made of durable elastic EPP,
100 % insulated valves and fittings - excellent ventilation and cooling of the pumps, minimal heat losses

Solar safety group
Solar pressure relief valve 6 bars, pressure gauge resistant to high temperatures 0-6 bars with valve, flat sealing connection for a diaphragm expansion tank, secondary side with pressure relief valve, 6 bars

Premounted solar standard pump or high-efficiency pump by Wilo or Grundfos

Pump can be isolated, so that it can be replaced without draining
Flush and fill valves integrated
two fill and drain valves permit flushing and filling the system

Flowmeter
with adjustable flow limiter and function control device, for temperatures up to 120 °C, measuring range 5-40 l/min

Safety instructions
The installation and commissioning as well as the connection of electrical components require technical knowledge commensurate with a recognised vocational qualification as a fitter for plumbing, heating and air conditioning technology, or a profession requiring a comparable level of knowledge [specialist].
The following must be observed during installation and commissioning:
- relevant local and national regulations
- accident prevention regulations of the professional association
- instructions and safety instructions mentioned in these instructions.

WARNING
Danger of scalding due to the escape of hot fluids!
With pressure relief valves, there is a risk of scalding due to the escape of vapour or hot fluid.
Please ensure for each pressure relief valve that no personal injury or material damage may occur due to possibly escaping medium.
- Install a discharge line.
- Observe the instructions regarding the pressure relief valve.
- The pressures for the expansion tank calculated by the plant designer and the operating pressure of the installation must be set.

CAUTION
Personal injury and material damage due to overpressure!
Closing both ball valves in the primary circuit will separate the safety group from the heat exchanger. A rise in temperature in the storage tank may result in high pressures, which may lead to personal injury and material damage!
- Only close the ball valves for service and maintenance.

CAUTION
Risk of burns!
Valves, fittings and pump may heat up to more than 100 °C during operation.
The insulating shell must remain closed during operation.

NOTICE
Material damage due to mineral oils!
Mineral oil products cause lasting damage to seals made of EPDM, whereby the sealant properties get lost. We do not assume liability nor provide warranty for damage to property resulting from sealants damaged in this way.
- It is imperative to avoid that the EPDM sealing elements of the unit get in contact with substances containing mineral oils.
- Use a lubricant based on silicone or polyalkylene and free from mineral oils, such as Unisilikon L250L and Syntheso Glep 1 of the Klüber company or a silicone spray.